Township of Freehold Seal
Blue Stars Image
 
 
 


Permit Application Requirements

Categories:

Deck
Fence
Shed
Siding/Roofing
Signs
Plumbing Work
Electrical Work
Inground and Public Pools
Above Ground Pools
Heating/AC systems
Interior Alterations - Residential
Interior Alterations - Commercial
Additions - Residential
Additions - Commercial
New Single Family Dwellings
New Construction - Commercial

Deck

Permit Application Requirements:


1. Complete application- jacket, building subcode and certificate application.
2. Survey of property to show location and size of proposed deck.
3. Two sets of detailed drawings of deck.
4. Permit will be processed for Zoning approval.
5. All contractors must provide a copy of the Home Improvement Contractors Certification. Applications will not be accepted without the required registration.
6.Plans to include:

  • Footing Locations
  • Footing depth - 36" minimum
  • Footing width - 12" minimun
  • Deck length, width and height
  • Stair details and location
  • Stair riser height - 8 1/4" maximum
  • Stair tread depth - 9" minimum
  • Stair width - 36" minimum
  • Handrail height - 30"-38" on at least 1 side with 3 or more risers, graspable - 1-1/4" to 2-5/8" in diameter. Ends will be returned, or shall terminate the newel posts or safety terminals
  • Guardrail height 36" minimum when more than 30" above grade
  • Baluster spacing less than 4" in-between at widest space
  • Size and spacing of posts, girders and joists
  • Detail of girder with size and spans
  • Detail of floor joists, size and spans
  • Flooring type
  • Ledget size, bolt size, and layout detail
  • Flashing detail, drip cap flashing is required, aluminum cannot be used
  • All hardware must e rust resistant, NO screws allowed on joist hangers
  • Need grade and species of lumber
7.Inspections Required:
  • Footings, when the holes are complete, before concrete is poured. ledger must be bolted inplace with drip cap flashing for footing inspection
  • framing or open deck is required with stairs installed
  • Final when deck is completely finished
8.Payment of permit application fee.

Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Fence

Permit Application Requirements: Privacy Fences require a Zoning Permit ONLY. Pool Barrier fences require a construction permit

1. Complete permit application package, jacket, building subcode and certificate application.
2. Survey of property to indicate proposed location.
3.All contractors must possess a "Home Improvement Contractors Certification" from the New Jersey State Attorney General's Office
4. Payment of permit application fee.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Shed

Permit Application Requirements 100 Sq ft and under requires a Zoning Permit Only. 100 Sq ft and over, maximun height is 16' high, requires a Construction Permit:

1. Complete permit application, jacket, building subcode and certificate application.
2.Two sets of detailed drawings fro shed, or brochure on pre-fab shed.
3. All sheds shall be placed on 4" of stone or 4" concrete slab, and to be anchored
4. All contractors must possess a "Home Improvement Contractors Certification" from the New Jersey State Attorney General's Office 5.All permits will be processed through Zoning prior to Construction plan review.
6. Payment of permit application fee.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Siding/Roofing

Permit Application Requirements:

1. Bulding subcode form, jacket and certificate application
2. Work may be performed by homeowner if single family, owner occupied or by a registered contractor.
3. All contractors must possess a "Home Improvement Contractors Certification" from the New Jersey State Attorney Generals Office.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Signs

Replacement sign – If using the same anchor fixtures & electrical, no construction permit required. A sign permit through the Zoning Office is required.

New sign - Construction permit application. Sign permit through the Zoning Office.

Construction permit application
1. Complete permit application; jacket, building subcode, electrical- if applicable,and certificate application.
2. Two sets of sealed drawings for proposed sign.

Sign permit application/Zoning application
1. Complete application.
2. Two sets of sealed drawings for proposed sign.
3. Survey to show location of sign (if freestanding)

Permit Application Requirements:
1. Complete application.
2.Copy of estimate or a list of materials and total cost.
3. Payment of permit application fee.

Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Electrical Work

Permit Application Requirements:

1. Complete permit application; jacket, electric subcode, and certificate application.
2. Electrical wiring requires a diagram of the work.
3. Work may be performed by homeowner, if single family, owner occupied, detached, or by a licensed contractor.

4. In case of licensed contractor, electrical subcode must be signed and sealed by the contractor.

5. Payment of permit application fee.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner
of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Plumbing Work

Permit Application Requirements:

1. Complete permit application; jacket, electric subcode, and certificate application.

2. Gas piping requires a diagram of the work.
3. Work may be performed by homeowner, if single family, owner occupied, detached, or by a licensed contractor.

4. In case of licensed contractor, plumbing subcode must be signed and sealed by the contractor.

5. Payment of permit application fee.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner
of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Pools (Inground and Public Pools)

Permit Application Requirements:

1. All contractors must possess a "Home Improvement Contractors Certification" from the new Jersey State Attorney Generals Office.
2. Complete permit package including jacket, building, electric and plumbing subcodes, certificate application, and homeowners pool certification.
3. Survey of property to include lot grading requirements, and proposed location of pool.
4. Fence must be shown on survey regardless of proposed or existing.
5. Pool barrier fences; gate must open outward, be self closing and self latching. Base of the fence must be to grade and not to exceed 2".
6. Inground pools - sealed specifications of the pool, two sets.
7. Brochures on pool, filter, and pump.
8. If the pool is to be heated, a brochure on the heating unit and gas piping diagram is required.
9. Prior to a final inspection a Diving Board Certification must be submitted and approved.
10.All pools will be processed for Zoning Department and Engineering Department approvals.
11. Public Poolswill also be processed for Health Department approval in addition to Zoning and Engineering.
12. Public Poolswill be required to have bonding and grounding certification.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner
of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Pools (Aboveground Pools)

Permit Application Requirements:

1. All contractors must possess a "Home Improvement Contractors Certification" from the new Jersey State Attorney Generals Office.
2. Complete permit package including jacket, building, electric and plumbing subcodes, certificate application, and homeowners pool certification.
3. Survey of property to show location of pool and distances.
4. On the survey, it must be indicated how the pool will be protected. both new and existing fences should be indicated.
5. Pool barrier fences; gate must open outward, be self closing and self latching. Base of the fence must be to grade and not to exceed 2".
6. Brochures on pool, filter, and pump.
7. If the pool is to be heated, a brochure on the heating unit and gas piping diagram is required.
8.All pools will be processed for Zoning Department and Engineering Department approvals.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner
of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Heating/AC Systems

Permit Application Requirements:

1. Complete permit application, jacket, electric, plumbing and electrical subcodes, and certificate application.
2. Brochure on heating/ac unit.
3. Location of proposed unit must be indicated on the permit application, ie: attic, garage, basement, utility room, etc.
4. new heating units must have a chimney certification from completed and signed.
5. A carbon monoxide detector must be installed within 10' of the bedroom areas.
6.Gas piping diagram.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Interior Alterations - Residential

Permit Application Requirements:

1. Complete permit application package.
2. Copy of estimate/proposal showing total cost of the project. If a homeowner is performing his own work, a list of materials and the cost of the project is required.
3. Detailed drawings of the proposed work, including electrical wiring and gas piping diagram. Homeowners may draw their own plans. If drawn by a contractor, must be signed and sealed by a licensed architect or engineer.
4. All Contractors must possess Home Improvement Contrractors Certification issued by the State Attorney Generals Offices, and provide a valid copy of this certification.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Interior Alterations - Commercial

Permit Application Requirements:

1. Complete permit application package.
2. Copy of estimate/proposal showing total cost of project.
3. Detailed drawings of the project signed and sealed by a licensed architect or engineer.
4. Detailed drwaings must include electrical wiring diagram and gas piping diagram.
5. If the business is a food establishment, applicant must obtain Health
    Department approval prior to the permit application submission.
6. A zoning application must be filed with the Zoning Officer.
7. All contractors must possess Home Improvement Contractors Certification issued by the State Attorney Generals Office, and provide a valid copy of this certification.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Additions - Residential

Permit Application Requirements:

1. Complete permit application, jacket, building, electric, plumbing and fire subcodes, certification application.
2.All contractors must possess a "Home Improvement Contractors Certification" from the New Jersey State Attorney General's Office.
3. Copy of survey to show proposed location of addition.
4. two sets of drawings, signed and sealed be architect or drawn by homeowner. Contractor may not draw structural plans. Licenses Plumbers and Electricians may draw and seal plumbing and electric plans.
5. Plans to Include: Building

  • Basement foundation; plan of footings, size and depth and foundation. Size of walls, block or concrete, height of walls, height of backfill.
  • Crawl Space - Show size and height of walls, vents and access.
  • Slabs - 4" of concrete and reinforcement wire, 4" stone, 6 mil vapor barrier with radon pipong.
  • Frame - Species and grade of all lumber
  • Floor Joists - size and span of all joists, TJI's or truss - 2 sets
  • Flooring - Material being used
  • Framing - framing detail on walls, size of lumber, header sizes, size of girders being used. If manufactured lumber, must be sealed. Sheathing and siding.
  • First Floor Plan - ceiling - size and spans
  • Roof - size and spans, if truss - 2 sets plans, plywood for roofing material, venting of roof, attic access, insulation in walls, floors and ceilings.
  • Heat loss calculations and HVAC layouts
  • Windows and doors.
  • Tempered glass by all tubs and/or Jacuzzi's

6. Electric - wiring diagram required
7. Plumbing - plumbing and gas drawings
8. Fire - CO alarms and smoke detectors required by Code
9. permit applications will be processed through Zoning.
10. Permit application will be processed through Health Department if dwelling is on septic and adding a bedroom.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


Additions - Commercial

Permit Application Requirements:

1. Prior Planning Board/Zoning Board approval.
2. Complete application.
3. Copy of survey.
4. Plans signed and sealed by licensed architect or engineer.
5. Copy of estimate or proposal.
6. If the business is a food establishment, applicant must obtain Health
    Department approval prior to the permit application approval.
7. Electrical wiring diagram or gas piping diagram are required.
8. Mount Laurel contribution may be required. Applicant will be advised on an
    individual basis of this requirement.
9. Payment of permit application fee.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


New Single Family Dwelling

Permit Application Requirements:

1. Permit Package - Homeowner may sign as their own agent, Contractors must sign and seal appropriate subcodes and must provide their Federal Employment Number or Social Security Number
2. Building Subcode Technical Section - Must provide cubic footage of dwelling
3.Electric Subcode Technical Section - A WR# (work request#)N#(notification #) obtained from GPU is required for a service inspection
4. Two sets of plans must be submitted and must be sealed by a licensed architect or engineer. Plans must include radon mitigation
5. If well and septic system is to be installed, application and plans must be submitted to the Health Department at the time of permit submission.
6. Survey of the property.
7. Shade Tree Commission - tree removal permit.
8. Mount Laurel contribution - worksheet will be forwarded to the Township Tax
    Assessor for calculation. Fifty percent (50%) payment will be required prior to
    permit issuance, and fifty percent (50%) prior to the certificate of occupancy
    issuance.
9. Dig Number - Homeowner/Contractor must obtain "clearance to dig" number by calling 1-800-272-1000.
10.Developers must provide a copy of the Builders Registration License; Proto-type plans must be documented with a letter from the Architect stating that the plans are to be used as such. Proto-type processing will be approved for developments building IDENTICAL MODEDLS ONLY.
11.Additional inspections may be required on fire damage, pools, roofing, siding and fences; Final inspections are required for each applicable code area before a final occupancy/approval may be issued.
12.An as buildt survey/foundation location is required prior to foundation inspection
13.A copy of the Township Construction Permit is required for construction debris to be accepted at the Freehold Township Recycling Center.
14.Payment of permit application fee.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top


New Construction - Commercial

Permit Application Requirements:

1. Prior Planning/Zoning Board approval.
2. Complete application.
3. Two sets of plans signed and sealed by a licensed architect or engineer.
4. Survey of the property.
5. If business is a food establishment, Health Department approval is required.
6. Engineering Department approval prior to building permit issuance.
7. Freehold Soil Conservation approval.
8. Mount Laurel contribution - worksheet will be forwarded to the Township Tax
    Assessor for calculation. Fifty percent (50%) payment will be required prior to
    permit issuance, and fifty percent (50%) prior to the certificate of occupancy
    issuance.
9. Zoning permit application must be submitted to the Zoning Officer.
10. Payment of permit application fee.


Applications may be obtained via this webpage or at the Construction Department which is located adjacent to the Municipal Building at 1 Municipal Plaza on the corner of Schanck and Stillwells Corner Roads or by calling (732) 294-2050.
Back To The Top

 

One Municipal Plaza, Freehold, NJ 07728            Phone: 732.294.2000           Fax: 732.462.7910            Contact Us            Site Map